Top-Discharge Outdoor Units

Top-discharge condensing units, 2–5 ton, with GMCC compressors and DC fan motors.

Refrigerant:R-32R-410A

Specifications

Top-Discharge Outdoor Units — key specifications
ParameterValue
Capacity2 – 5 ton
Power supply220V / 60Hz / 1Ph
CompressorGMCC
Fan motorDC fan motor
Communication24V
DefrostAutomatic or manual
RefrigerantR-32 / R-410A

Values as published in the 2026 product catalogue. Ask us for the model-level submittal sheet before specifying.

Features

  • ✓Top-discharge airflow for restricted side-clearance installations

Overview

A top-discharge condensing unit rejects air upward instead of sideways. This family covers 2 to 5 ton units on a 220V / 60Hz / single-phase supply, with a rotary compressor, a DC fan motor, a 24V communication interface and automatic or manual defrost. R-32 and R-410A are both published for the family.

It solves a layout problem rather than a capacity problem: equipment pads where the sides are boxed in by a wall, a fence, a screen or the next unit in a row. It belongs to the same 24V indoor portfolio as the rest of the split range, so cassette, floor-ceiling, ducted, AHU and A-coil units can be quoted around it. No efficiency rating is published at family level.

Where it is used

  • Replacement of an aging 24V condensing unit on a pad with restricted side clearance
  • New installations where outdoor units sit close together in a row or enclosure
  • Wall-adjacent and screened pads where airflow has to go up and away
  • Standard 220V single-phase split systems on a 24V thermostat or controller

Selection & installation notes

  1. 01

    Confirm the clearances above and around the unit from the installation manual before the pad is set; a top-discharge cabinet needs an unobstructed upward path.

  2. 02

    Confirm the refrigerant per model — R-32 and R-410A are both published and the two are not interchangeable.

  3. 03

    Defrost is published as automatic or manual; confirm which applies to the model and how a manual cycle is initiated.

  4. 04

    State the indoor unit and the 24V controller at enquiry so the match and control interface are checked together.

  5. 05

    No efficiency rating is published for this family. If one is needed for a specification, request the per-model figure and its test conditions.

Common questions

When should a top-discharge unit be used instead of a side-discharge unit?

Where the sides of the pad are obstructed — units in a row, screened pads, equipment close to a wall. Both families use the same 24V indoor portfolio, so the choice comes down to pad layout.

Is it cooling only or a heat pump?

The published data gives automatic or manual defrost, which is a heating-mode function. Heating capacity and operating range are not published at family level, so confirm them per model.

What compressor and fan motor does it use?

A rotary compressor with a DC fan motor, on all models as published.

Which capacities are available?

The family covers 2 to 5 ton and the catalogue gives 2, 3, 4 and 5 ton sizes. Exact capacities and indoor pairings are confirmed per model.