Commercial equipment

Supporting components and optimised selection design across commercial equipment types — rooftop fixed speed and inverter units, VRF, chillers, and modular air-to-water chillers and heat pumps.

Product families in this solution

Design decisions behind this solution

  1. 01

    Fix the unit type and capacity band first. The rooftop range covers 3–30 ton, with 3 and 5 ton standard and a line-up of 6.2 / 7.5 / 8.5 / 10 / 12.5 / 15 / 17.5 / 20 / 25 / 30 ton, plus deep customisation to 50–100 ton. Power is 220V / 60Hz / 1Ph, 3-phase at 5 ton.

  2. 02

    Decide which factory options belong in the unit at order: the economizer or outdoor-air package, energy recovery, hot gas reheat, electric heat, heat pump heating, higher MERV filtration, higher static pressure and BACnet or Modbus options are all factory-selected.

  3. 03

    For DOAS or make-up air work, decide whether the unit conditions outdoor air only or delivers ventilation air and space conditioning together. The answer sets airflow, tempering load and cabinet arrangement.

  4. 04

    Decide how capacity is staged where the load varies. VRF systems and modular air-to-water chillers and heat pumps are the multi-zone, staged-capacity routes, selected against the project load with system design support.

  5. 05

    Where a building management system is present, name the protocol and points list with the quotation. The points list is what the controls contractor prices, and communication is a factory option on the rooftop range.

How it connects to the rest of the system

Common questions

What is the rooftop capacity range, and can it be customised beyond it?

From 3 to 30 ton, with 3 and 5 ton standard and a line-up of 6.2 / 7.5 / 8.5 / 10 / 12.5 / 15 / 17.5 / 20 / 25 / 30 ton; above that, deep customisation covers 50–100 ton including DOAS and make-up air. Power is 220V / 60Hz / 1Ph.

What information do you need to make a selection?

The cooling and heating load, whether the duty is space conditioning, DOAS or make-up air, the outdoor-air quantity, filtration class and external static pressure, the electrical service available and any BMS protocol.

Is BACnet or Modbus included, or is it an option?

It is a factory option on the rooftop range, ordered with the unit. BACnet and Modbus describe communication protocol support rather than a certification, and the points list should be agreed at quotation.

Can you provide drawings and submittals for the coordinated model?

Model-level submittal sheets, selection and match data, and drawings are issued per model on request, so the coordinated drawing matches the unit supplied. Certification evidence is issued only where we hold verified certificates.